Scope

The Commonplace Robotics control for the igus robolink robots comes with one digital input / output module with seven digital inputs (24V via Optocoupler) and 7 digital outputs (24V max 300 mA via reed relay). If these DIOs are not enough it is possible to add two further digital input / output modules to the control.

Mechanical Integration

Caution.png Do not hotplug! Disconnect the control from the power source before changing components of plugging / unplugging cables!

  • Add the bus extenders to the control. They have to be pressed in the C-Rail and pressed to the existing control beneath the Digital IO module.
  • Plug the additional digital IO module
  • Set the CAN ID with the selector on the front face:
    • First (already existing) IO module: 0 (this results in CAN ID 0x70 = 112)
    • Second (additional) IO module: 2 (this results in CAN ID 0x80 = 128)
    • Third (additional) IO module: 4 (this results in CAN ID 0x90 = 144)

DIO_bus_settings.png

Electrical Integration

DIO pinout.png Digital Inputs:

  • Connect the ground pin (Output connector 1, to

GND

  • Supply 24V to one of the input pins
  • Example on the left: 24V via switch to input pin 4
  • Result in CPRog: digital input Din24 is triggered