For the Mover robots the joint controller parameter define how the robot moves: more smooth, or more precise

  • Smooth motion: Position-P = 0,5, Velocity-P = 0.5, I and D values 0
  • Precise motion: Position-P = 1.5, Velocity-P = 0.6, I and D values 0

Robots build in 2016 or later should set the joint 4 settings to Position-P = Velocity-P = 0.3. This joint features a motor with a better encoder.