Difference between revisions of "Additional DIO-Modules"

From Wiki
(Created page with "=Scope= The Commonplace Robotics control for the igus robolink robots comes with one digital input / output module with seven digital inputs (24V via Optocoupler) and 7 digita...")
 
Line 4: Line 4:
  
 
=Mechanical Integration=
 
=Mechanical Integration=
[[file:Warning.png|100px]]Do not hotplug! Disconnect the control from the power source before changing components of plugging / unplugging cables!  
+
[[file:Caution.png|frameless|50px] Do not hotplug! Disconnect the control from the power source before changing components of plugging / unplugging cables!  
  
Add the bus extenders to the control. They have to be pressed in the C-Rail and pressed to the existing control beneath the Digital IO module. Plug the additional digital IO module Set the CAN ID with the selector on the front face: o First (already existing) IO module:  0  (this results in CAN ID 0x70 = 112) o Second (additional) IO module:          2 (this results in CAN ID 0x80 = 128) o Third (additional) IO module:                4 (this results in CAN ID 0x90 = 144)
+
*Add the bus extenders to the control. They have to be pressed in the C-Rail and pressed to the existing control beneath the Digital IO module.  
 +
*Plug the additional digital IO module  
 +
*Set the CAN ID with the selector on the front face:  
 +
**First (already existing) IO module:  0  (this results in CAN ID 0x70 = 112)  
 +
**Second (additional) IO module:          2 (this results in CAN ID 0x80 = 128)  
 +
**Third (additional) IO module:                4 (this results in CAN ID 0x90 = 144)
 +
[[file:DIO_bus_settings.png|DIO_bus_settings.png]]

Revision as of 14:04, 18 June 2018

Scope

The Commonplace Robotics control for the igus robolink robots comes with one digital input / output module with seven digital inputs (24V via Optocoupler) and 7 digital outputs (24V max 300 mA via reed relay). If these DIOs are not enough it is possible to add two further digital input / output modules to the control.

Mechanical Integration

[[file:Caution.png|frameless|50px] Do not hotplug! Disconnect the control from the power source before changing components of plugging / unplugging cables!

  • Add the bus extenders to the control. They have to be pressed in the C-Rail and pressed to the existing control beneath the Digital IO module.
  • Plug the additional digital IO module
  • Set the CAN ID with the selector on the front face:
    • First (already existing) IO module: 0 (this results in CAN ID 0x70 = 112)
    • Second (additional) IO module: 2 (this results in CAN ID 0x80 = 128)
    • Third (additional) IO module: 4 (this results in CAN ID 0x90 = 144)

DIO_bus_settings.png