Difference between revisions of "Robot Hardware Troubleshooting"
From Wiki
Line 1: | Line 1: | ||
==Modular control electronics / robolink robots== | ==Modular control electronics / robolink robots== | ||
[[file:DIN-Rail-Module-LEDs.png|What do the LEDs of the DIN Rail Modules indicate?]] | [[file:DIN-Rail-Module-LEDs.png|What do the LEDs of the DIN Rail Modules indicate?]] | ||
− | {| class="wikitable" | + | {| class="wikitable"; vertical-align: top;" |
− | |||
! Problem !! Cause !! Correction | ! Problem !! Cause !! Correction | ||
|- | |- |
Revision as of 10:04, 12 May 2018
Modular control electronics / robolink robots
Problem | Cause | Correction |
---|---|---|
Excessively jerky movement or acceleration and stall of the last joint of a robolink robot during initial set up of the robot | Wrong encoder direction | Swap encoder direction of this joint |
Green LEDs on the rail modules are off | No power is supplied to the Modules | Check the power supply and the fuse. |
Motors do not move | Check the emergency stop state. The red LED on the support module most not be on. The LED indicates emergency stop | Deactivate emergency stop. |
The modules do not react to software commands. The green LEDs are not blinking, they are continuously on | There must not be an empty slot between the support module of the electronics and the joint modules. The CAN connection is interrupted by such an empty slot. | Ensure there is no empty slot between the modules |
The motor stalls: it does not finish a motion and increases in pitch of sound. | This happens, when the load of the motor was too high. | Check if there was a collision. If this happens several times increase the motor current, see chapter 7 of the manual. |
CPRog cannot connect | Another application may be using the CAN connection | Close or reset the PCAN-View software, if it is running. |